Current/Voltage Transformer Percent Test Set Manually Field Calibrator PT Detector

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 12months
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 4 Self-brands, check the Audit Report for more information
to see all verified strength labels (28)
  • Current/Voltage Transformer Percent Test Set Manually Field Calibrator PT Detector
  • Current/Voltage Transformer Percent Test Set Manually Field Calibrator PT Detector
  • Current/Voltage Transformer Percent Test Set Manually Field Calibrator PT Detector
Find Similar Products
  • Overview
  • Product Description
  • Products Show
  • Our Company
  • Production Line
  • Filed Test&Service
  • Packing & Delivery
  • Our Certifications
  • FAQ
Overview

Basic Info.

Model NO.
HGQL-H
Type
Portable
Accuracy Grade
0.5
Load Way
Electronic Load
Display
LCD Touch Screen
Weight
10kg
Power Source
AC220V
Power Consumption
20va
Accuracy Level
0.05s
Support
OEM,Wholesales,Dropshipping
Product Name
Secondary Voltage Drop and Load Tester
Standard
ISO
Application
Electrics
Customized Support
OEM,ODM,Software Reengineering
Power
Electronic
Transport Package
Wooden Box
Specification
24kg
Trademark
HUAYI
Origin
Hubei, China
Production Capacity
100PCS/Month

Product Description

Product Description

Introduction

Current/Voltage Transformer Percent Test Set Manually Field Calibrator PT Detector
 
 
Apply to: CT field calibrator is designed with advanced test technology and large electrical wiring, complied with national
standard.
It solves the problems of high working intensity and complicated operation during calibrate CT in the field, stable performance and strong functional.

Features

1. This calibrator combine the recursive method and Potential difference method for measuring the error of CT, convenient to work on field.
2. No need standard CT, current device, load cabinet, voltage regulation control cabinet and high current conductor, it can calibrate CT through sample test wiring and operation. Greatly reduces the working intensity and improves the working efficiency.
3. With internal standard CT same ratio as tested CT, the accuracy is 0.05 and can measure the ratio and no-load error of tested CT accurately, then calculate the error combined with the test result of reactance and admittance.
4. Adopt different frequency power source close to power frequency to prevent electromagnetic radiation and series interference.
5. The test range is wide, up to 5A/5A~25000A/5A or 25A/1A~5000A/1A
6. With transformer ratio, secondary winding resistance test function
7. Equipped with 640×480 high resolution LCD display, with humanized interface and operation, using touch screen to assist the operation, convenient and fast.
8. Adopts accurate software algorithm, improved the accuracy of measurement.
9. Intelligently judge the condition of external wiring and indicate the error of wiring, ratio, polarity.
10. Automatically integrate the test data, and judge whether it is out of tolerance or not. display the out-of-tolerance data with reverse black, so that the data of transformer are visual.
11. Directly issue the on-site verification conclusion, qualified or unqualified.
12.The memory with high capacity can store up to 1000 pieces of field test data. With printer, test data can be printed on site.
13. Equipped with engineering plastic mold chassis to prevent vibration and pressure, ensure the safety of operators and equipment during high pressure test on site.
Technology Parameters
1. MEASUREMENT OF CT ERROR
Accuracy
1/3 of tested CT limited error
Measurement range
5A/5A~25000A/5A or 25A/1A~5000A/1A
Working range of tested CT
1%~120%
Secondary on load
2.5VA~300VA,COSφ=0.1~1.0
Working range of tested PT
1.0,0.5,0.5S,0.2, 0.2S
Measurement error of resistance and admittance
≤5.0%
Range:R:0.00Ω~20.0Ω;0.000mS~100.0mS
 
2. PT CALIBRATOR
Basic error
Cophase component:△X=±(X×2%+Y×2%±2);△Y=±(X×2%+Y×2%±5d) ;"X","Y"--Display value of instrument ;"5d"--Instrument quantization error
Percent meter:1 level
Test range:f:0.0000%~200.0%; δ:0.000mS~999.9mS
Rated working voltage
100/3V,100/√3V,100V
Working range of tested PT
20%~120%
 
3. BASIC PARAMETERS
Power consumption
20VA
Accuracy
0.05S
Max dimension L×W×H
46×35×13.5(cm)
Weight
10kg

Accessory

 
Serial Number
Name
Amount
1
Mainframe
one
2
Power line
one
3
Test wire bag
one
4
Test clap
one
5
Serial line
one
6
Printing paper
one
7
Specification
one
8
Inspection Report
one
9
Certification
one
Products Show
Current/Voltage Transformer Percent Test Set Manually Field Calibrator PT Detector
Our Company
 
About HUAYI
Wuhan HUAYI Electric was founded in 2005, located in Wuhan City, China. We are a professional manufacturer of electric testing equipment with over 15 years industry experience, engaged in high voltage tester with high performance, good quality, customized specification and easy operation. ISO qualified factory, strong R&D team and after-sales engineers make us gain good feedback from wide customers. HUAYI is committed to preventative, maintenance, troubleshooting and commissioning all the time. Our products are involved inAC/DC Hipot tester,series resonant test system, transformer tester, relay tester, circuit breaker/switch tester, oil/SF6 tester,cable testerand other electric instruments, widely adapted to electric power, water conservation, oil, railway, mine, chemical.
 
 
Current/Voltage Transformer Percent Test Set Manually Field Calibrator PT Detector
Production Line
We are professional manufacturer in China, have own production line and R&D team, providing best price and quality.
 
Current/Voltage Transformer Percent Test Set Manually Field Calibrator PT Detector
Filed Test&Service
 
 
Current/Voltage Transformer Percent Test Set Manually Field Calibrator PT Detector
Current/Voltage Transformer Percent Test Set Manually Field Calibrator PT Detector
 
Packing & Delivery
 
Current/Voltage Transformer Percent Test Set Manually Field Calibrator PT Detector
 
 
 
Our Certifications
Current/Voltage Transformer Percent Test Set Manually Field Calibrator PT Detector
FAQ

1. How can I choose the suitable one?
Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.

2.What is the mini order quantity?
MOQ: generally 1 unit/piece/set
3. How can I pay?
Dear customer, we accept many payment term, such as T/T, Western Union...

4.Is will be broken during transport?
Dear customer, please do not worry, we do standard export package.

5.What should I do if I do not know how to use?
Dear customer, please do not worry, manual user will be sent together, you can also contact us with more technological support.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier